This article describes how to create test groups so you can use multiple tests with quality orders in Microsoft Dynamics 365 Supply Chain Management.
Use the Test groups page to set up, edit, and view test groups and the individual tests that you assign to them. The upper part of the page shows the test groups, and the lower part shows the tests that are assigned to a selected test group.
Assign several policies to a test group, such as a sampling plan, an acceptable quality level (AQL), and the requirement for destructive testing. When you assign an individual test to a test group, define additional information, such as the sequence, documents, and validity dates. For a quantitative test, the information that you define also includes the acceptable measurement values. For a qualitative test, the information includes the test variable and default outcome.
The test group that you assign to a quality order defines the default set of tests that you must perform on the specified item. However, you can add, delete, or change tests for the quality order. The system reports test results for each test on a quality order.
When you define a test group, you can optionally specify an item sampling. Use item samplings to define the amount of the product that must be tested. Learn more in Quality management item sampling. You can also indicate whether the tests in a test group are destructive. In a destructive test, the item sampling is destroyed, and the quantity is removed from the on-hand inventory.
Example of a test group
A manufacturing company defines a test group for each variation of its quality guidelines. The various test groups reflect differences in the sampling plans, the sets of tests that must be performed together, the AQL, and other factors. For quantitative tests, there are also differences in the acceptable measurement values. To enforce its quality guidelines, the company assigns a test group to each rule that is used to automatically generate quality orders on the Quality associations page. It also assigns a test group to quality orders that are manually created.
Create a test group
To create a test group, follow these steps.
Go to Inventory management > Setup > Quality control > Test groups.
On the Action Pane, select New to add a row to the grid in the upper part of the page. Then set the following fields for the new row:
- Test group – Enter a unique ID or name for the test group.
- Description – Enter a detailed description of the test group.
- Acceptable quality level – Enter the total percentage of test results that must pass for the group of tests to be considered passed.
- Item sampling – Select an item sampling. Learn more in Quality management item sampling.
- Destructive – Select this check box to indicate that the test group destroys the items that are tested.
While the new row is still selected, select the General tab in the upper part of the page. Some of the settings for the test group that you select on the Overview tab are repeated here. In addition, you can set the following fields for the group:
- Update inventory batch attribute – When you set this option to Yes here, it automatically sets to Yes for every new test that you add to the test group in the lower part of the page.
- Update batch disposition – When you set this option to Yes, if the item that you're testing is batch controlled, the batch disposition automatically updates with the value selected in the Failed quality order batch disposition or Passed quality order batch disposition field.
- Failed quality order batch disposition – Select the batch disposition code that should be assigned when a quality order that includes this test group fails because it doesn't meet the AQL.
- Passed quality order batch disposition – Select the batch disposition code that should be assigned when a quality order that includes this test group passes because it meets the AQL.
- Update inventory status – When you set this option to Yes, if Inventory status is enabled on the storage dimension group for the item that you're testing, the status automatically updates with the status selected in the Failed quality order status or Passed quality order status field.
- Failed quality order status – Select the inventory status that should be assigned to the item when a quality order that includes this test group fails because it doesn't meet the AQL.
- Passed quality order status – Select the inventory status that should be assigned to the item when a quality order that includes this test group passes because it meets the AQL.
Add a qualitative test to a test group
To add a qualitative test to a test group, follow these steps.
Go to Inventory management > Setup > Quality control > Test groups.
On the Overview tab in the upper part of the page, select the test group that you want to add a test to.
In the lower part of the page, on the Overview tab, select Add on the toolbar to add a row to the grid. Then set the following fields for the new row:
Sequence number – Enter an integer to specify the order that the tests should be performed in. Tests that have smaller sequence numbers run before tests that have larger sequence numbers.
Note
Leave a gap between sequence numbers. For example, set the Sequence number field to 10 for your first test, and then increment the value by 10 for each additional test. In this way, you can add new tests later without having to delete and re-create the lines to put them in the desired order.
Test – Select the test that you want to perform. For a qualitative test, select a test where the Type field is set to Option.
Effective – Select the first date when the test is valid. If you leave this field blank, there's no limit.
Expiration – Select the last date when the test is valid. If you leave this field blank or set it to Never, there's no limit.
Test value determination – Select how an AQL should be determined when multiple results are recorded for the same test. For a qualitative test, only Manual can be selected. If you select one of the other values (Average, Minimum, or Maximum), you receive an error message when you save the test group.
Attribute – If you want to record test results on a batch attribute, select the attribute here, and select the Update inventory batch attribute check box.
Update inventory batch attribute – Select this check box to record test results for the batch attribute that is selected in the Attribute field.
In the lower part of the page, select the General tab. Some of the settings for the test selected on the Overview tab are repeated here. In addition, you can set the following fields for the test:
- Certificate of analysis report – Set this option to Yes to indicate that the test results should be printed on the certificate of analysis (CoA). This report can be generated from the quality order.
- Action on failure – Select either Accept or Fail to indicate whether the test should pass or fail if the AQL for it isn't met.
- Acceptable quality level – Enter the total percentage of test results that must pass for the test to be considered passed.
In the lower part of the page, on the Test tab, set the following fields:
- Variable – Select the test variable to record the qualitative test results for.
- Default outcome – Select the default outcome that should be recorded for the test results.
- Test instrument – Select the device that should be used for the test. If a test instrument is defined, it's automatically entered for the test in the test group.
Close the page.
Add a quantitative test to a test group
To add a quantitative test to a test group, follow these steps.
Go to Inventory management > Setup > Quality control > Test groups.
On the Overview tab in the upper part of the page, select the test group that you want to add a test to.
In the lower part of the page, on the Overview tab, select Add on the toolbar to add a row to the grid. Then set the following fields for the new row:
Sequence number – Enter an integer to specify the order that the tests should be performed in. Tests that have smaller sequence numbers run before tests that have larger sequence numbers.
Tip
You should leave a gap between sequence numbers. For example, set the Sequence number field to 10 for your first test, and then increment the value by 10 for each additional test. In this way, you can add new tests later without having to delete and re-create the lines to put them in the desired order.
Test – Select the test that you want to perform. For a quantitative test, select a test where the Type field is set to Fraction or Integer.
Effective – Select the first date when the test is valid. If you leave this field blank, there's no limit.
Expiration – Select the last date when the test is valid. If you leave this field blank or set it to Never, there's no limit.
Test value determination – Select how an AQL should be determined when multiple results are recorded for the same test. The available options are Average, Minimum, Maximum, and Manual.
Attribute – If you want to record test results on a batch attribute, select the attribute here, and select the Update inventory batch attribute check box.
Update inventory batch attribute – Select this check box to record test results for the batch attribute that is selected in the Attribute field.
In the lower part of the page, select the General tab. Some of the settings for the test selected on the Overview tab are repeated here. In addition, you can set the following fields for the test:
- Certificate of analysis report – Set this option to Yes to indicate that the test results should be printed on the CoA. This report can be generated from the quality order.
- Action on failure – Select either Accept or Fail to indicate whether the test should pass or fail if the AQL for it isn't met.
- Acceptable quality level – Enter the total percentage of test results that must pass for the test to be considered passed.
In the lower part of the page, on the Test tab, set the following fields:
- Standard – Enter the amount (integer or fraction) that is expected for the test results. The value that you enter is entered by default in the test results. Additionally, it automatically enters as a default value in the Min and Max fields.
- Min – Enter the minimum allowed value for the test results. The value that you enter must be less than the amount that is set in the Standard field. When you update the Min field, the Min tolerance (%) field is automatically updated. Likewise, when you update the Min tolerance (%) field, the Min field is automatically updated.
- Max – Enter the maximum allowed value for the test results. The value that you enter must be more than the amount that is set in the Standard field. When you update the Max field, the Max tolerance (%) field is automatically updated. Likewise, when you update the Max tolerance (%) field, the Max field is automatically updated.
- Test instrument – Select the device that should be used for the test. If a test instrument is defined, it's automatically entered for the test in the test group.